Highest limit of the pressure measurement, kgf/cm2 |
250/400/600 |
Lowest limit of the pressure measurement, kgf/cm2 |
0 |
Accuracy, %FS |
± 1.5 |
Calibration interval, months |
36 |
Ex marking, TR CU 012/2011 |
1 Еx ib IIB Т4 Gb |
Ex marking, ATEX |
II 2G Ex ib IIA T3 Gb |
Power supply range, VDC |
12…18 |
Ingress protection |
IP 66 |
Communication interface |
RS-485 |
Communication protocol |
Modbus |
Analog output range, mA |
4…20 |
Ambient temperature range, °С |
-45…+65 |
Weight, kg / Масса, кг |
2.4 |
Dimensions, mm, max. |
Ø90 x 156 |
The TP-140D(MA) Pressure Transducer is designed to measure liquid pressure in the pipelines with neutral and aggressive media without a phase separator. The sensor has an additional output of 4...20 mA for connection to 3rd party instrumentation systems and is intended for installation in the 2” conic quick-release coupling
Capabilities
Design features